Home › Schneider Electric › MasterPacT MTZ (MicroLogic X)

Schneider Electric MasterPacT MTZ (MicroLogic X)

Solar inverter by Schneider Electric. Compatibility with energy supplier apps, Home Assistant and evcc.

At a glance

Device typeSolar inverter [evcc template, 2026-10-19]
evcc supportYes
schneider-micrologic (Modbus RTU, Modbus TCP) [evcc template, 2026-10-19]
ConnectionModbus RTU (RS485)Modbus TCP (inferred from evcc template parameters) [evcc template, 2026-10-19]
Local control (no cloud)Yes via evcc's connection type [evcc template, 2026-10-19]
Home AssistantUnknown know this? tell us (brand not yet checked)
Known firmware notesUnknown know this? tell us

Energy supplier apps

Supplier lists are published per brand (sometimes with model conditions). A brand match does not guarantee your exact model works — check the linked page or the supplier's app.

Supplier / serviceStatus for Schneider Electric inverterSource
Frank Energie Not listed Schneider Electric is not on Frank Energie's inverter list [source, 2026-10-19]
Tibber Not listed Schneider Electric is not on Tibber's inverter list [source, 2026-10-19]
Zonneplan Not listed Zonneplan only lists its own hardware [source, 2026-10-19]
Eneco Unknown know this? tell us —
ANWB Energie Unknown know this? tell us —
Vattenfall Unknown know this? tell us —

Home Assistant integrations for Schneider Electric

Unknown know this? tell us — we have not yet checked Home Assistant support for Schneider Electric.

evcc details

Templateschneider-micrologic (meter; usages: grid, pv, charge) [source, 2026-10-19]
ConnectionModbus RTU (RS485)Modbus TCP (inferred)
CapabilitiesUnknown know this? tell us
Requirements
The trip unit has to be reachable over Modbus through a communication module: IFM (Modbus RTU) or IFE (Modbus TCP), or EIFE on MasterPacT MTZ. IFE and EIFE always use Modbus ID 255, the IFM uses the address set on its rotary switches. 4-pole versions measure the neutral directly. 3-pole versions need an external neutral voltage tap (ENVT) for this, connected and declared in the trip unit (system type 40 or 41). Without ENVT, power values are wrong whenever current flows in the neutral. The power flow sign has to be set with "EcoStruxure Power Commission" so that the normal direction of flow counts as positive. Factory setting: from the top terminals to the bottom ones.
[source, 2026-10-19]
Known caveatsNone listed in the evcc template.